TESTING REPORT

 

Report NO: L2270

Sample Name: Atmospheric Water Generator           Test Item: Immersion Test about Hygiene and Safety

Test Data:


The Drinking Water Standard Examination Method, Microbiological Index

The Drinking Water Standard Examination Method, Sensory Attributes and Physical Index

The Drinking Water Standard Examination Method, Metal Index

The Drinking Water Standard Examination Method, Organics Composite Index

 

Sample Name: Atmospheric Water Generator                       Processing Date: 2015-07-28
Sender: World Environmental Solutions                                  Testing Period: 2015/07/28-2015/09/15

 

RESULT

According to “Drinking Water Health Standards” (Ministry of Health 2001), Enclosure 4A “Sanitary Standard of Hygienic Safety and Function of Drinking Water’s Water Treatment Device – General Devices” to do hygiene and safety inspection.
The result shows that: the test result about chromaticity, Turbidity, Odor, Visible inclusions, Oxygen consumption (calculated as CO2), Lead, Cadmium (Cd), Mercury (Mg), Six valency, Chromium, Arsenic (As), Volatile phenol, total Bacterial, total Coliforms, Fecal Coliforms etc. and all are to the Standard –“Drinking Water Health Standards” (Ministry of Health 2001) Enclosure 4A “Sanitary Standard of Hygienic Safety and Function of Drinking Water’s Water Treatment Device – General Devices” about the General Devices.